000 02647cam  2200361za 4500
0019.830845
003CaOODSP
00520221107145623
007cr |||||||||||
008170119s1995    oncad   o    f000 0 eng d
040 |aCaOODSP|beng
041 |aeng|bfre
043 |an-cn---
0861 |aNH18-1/380-1995E-PDF
1001 |aBrown, W. C.|q(William Colin)
24510|aProgress report #3 |h[electronic resource] : |bmeasured pressure equalized performance of two precast concrete panels : performance of pressure equalized rainscreen walls, a collaborative research and development project / |cauthor, William C. Brown ; author, James M. Ullett ; author, W. Alan Dalgliesh.
24630|aMeasured pressure equalized performance of two precast concrete panels : |bperformance of pressure equalized rainscreen walls, a collaborative research and development project
260 |a[Ottawa] : |bCanada Mortgage and Housing Corporation, |c[1995]
300 |aiii, 16, [55] p. : |bill.
4901 |aResearch report
500 |a"Approved: Dr. S.A. Barakat, Head, Building Performance Laboratory."
500 |a"Report date: May 31, 1995."
520 |a"This report presents data from the experimental evaluation of two precast concrete sandwich panels which were supplied by the Canadian Precast Concrete Institute (CPCI). Each test specimen is 2.40 m high by 1.19 m. wide, and consists of a 100 mm thick precast concrete inner slab which acts as the air barrier, 50 mm of extruded polystyrene insulation, a 13 mm cavity, and a 64 mm precast concrete outer slab which acts as the rainscreen. The inner and outer slabs are connected by two vertical stainless steel trusses located 610 mm apart. The cavity of one specimen (Specimen 3) is a 13 mm air space, while the cavity of the other specimen (Specimen 4) is formed using 13 mm deep Miradrain™. Both cavities extend over the height and the width of the specimen. The experimental evaluation task consisted of pressure equalization, slab deflection, water penetration, and air leakage sub-tasks"--Executive summary, p. 1.
546 |aIncludes abstract in French.
69207|2gccst|aHousing
69207|2gccst|aConstruction materials
69207|2gccst|aTesting
7001 |aUllett, James M.
7001 |aDalgliesh, W. A.|q(William Alan)
7102 |aBuilding Performance Laboratory (Canada)
7102 |aCanada Mortgage and Housing Corporation.
830#0|aResearch report (Canada Mortgage and Housing Corporation : Online)|w(CaOODSP)9.506068
85640|qPDF|s3.12 MB|uhttps://publications.gc.ca/collections/collection_2017/schl-cmhc/nh18-1/NH18-1-380-1995-eng.pdf