The influence of termination configuration on the flow performance of flues / a study prepared for Canada Mortgage and Housing Corporation by Scanada Consultants Limited, Scanada Sheltair Consortium Inc. : NH18-1/400-1987E-PDF
"As part of its ongoing study of combustion venting problems in Canadian houses, Canada Mortgage and Housing Corporation engaged the Scanada Sheltair Consortium to conduct studies of several aspects of chimney flue performance, including: the influence of thermal and flow design parameters on the performance of chimneys, the performance of flues shared by gas furnaces and water heaters, the influence of flue caps and dampers on chimney performance, and the performance of sealed, insulated venting systems for oil furnaces. This report deals with one part of one of the above studies – the influence of flue caps on flue performance. The title has been changed to mention termination configuration rather than caps because performance data on capless flues is also of interest. The other studies are reported on separately"--Intro., p. 1.
Lien permanent pour cette publication :
publications.gc.ca/pub?id=9.831187&sl=1
Ministère/Organisme | Canada. Canada Mortgage and Housing Corporation. Research Division. Scanada Consultants Limited. |
---|---|
Titre | The influence of termination configuration on the flow performance of flues / a study prepared for Canada Mortgage and Housing Corporation by Scanada Consultants Limited, Scanada Sheltair Consortium Inc. |
Variante du titre | Influence of flue termination configuration |
Titre de la série | Research report |
Type de publication | Série - Voir l'enregistrement principal |
Langue | [Anglais] |
Format | Électronique |
Document électronique | |
Note(s) | Cover title. "Principal Consultants: John C. Haysom, Michael C. Swinton." "June 11, 1987." Includes bibliographical references (p. 31). The influence of termination configuration on the flow performance of flues /a study prepared for Canada Mortgage and Housing Corporation by Scanada Consultants Limited, Scanada Sheltair Consortium Inc. --Appendix A.Extract from Standard UL 441 "standard for gas vents" --Appendix B.Details of termination configurations tested --Appendix C.Performance testing of chimney flue caps /Rowan Williams Davies & Irwin Inc. --Appendix D.Further analysis of laboratory test results. |
Information sur la publication | [Ottawa] : Canada Mortgage and Housing Corporation, [1987] |
Auteur / Contributeur | Haysom, John C. Swinton, M. C. |
Description | xi, 67 p. : ill. |
Numéro de catalogue |
|
Descripteurs | Housing Heating Testing |