00000000nam##2200000za#4500
0019.611764
003CaOODSP
00520200327123116
007ta
008150406|1994||||xxc|||||     f|0| 0 eng|d
020 |a0-662-22895-2
040 |aCaOODSP|beng
043 |an-cn---
0861 |aM91-7/324-1994E
1101 |aCanada.|bNatural Resources Canada. |bCanada Centre for Mineral and Energy Technology.
24510|aDevelopment of a non-intrusive test for argon gas levels for high performance windows / |cby Bryan M. Latta et al.
260 |aOttawa - Ontario : |bNatural Resources Canada. |c1994.
300 |axi, 62p. : |bfigs., graphs, references, tables ; |c28 cm.
4901 |a[Technology report]
500 |a"This is an extension of work initiated under an earlier contract wherein a procedure for measuring the argon content of insulated glass units was found. The objective of the present report is to outline refinements to that electric discharge test procedure. The refinements were required in order to minimize the potential degradation of the glass and its coatings."--Abstract.
5203 |aThis is an extension of work initiated under an earlier contract wherein a procedure for measuring the argon content of insulated glass units was found. The objective of the present report is to outline refinements to that electric discharge test procedure. The refinements were required in order to minimize the potential degradation of the glass and its coatings.--Abstract
546 |aRésumés en français
563 |aRing binding
69007|aEnergy conservation|2gcpds
69007|aConstruction materials|2gcpds
7201 |aLatta, Bryan M.
830#0|a[Technology report]|w(CaOODSP)9.514782
986 |aCANMET Contract No. EA-0721-90-9432