000
| 02647nam 2200361za 4500 |
---|
001 | 9.830845 |
---|
003 | CaOODSP |
---|
005 | 20221107145623 |
---|
007 | cr ||||||||||| |
---|
008 | 170119s1995 oncad o f000 0 eng d |
---|
040 | |aCaOODSP|beng |
---|
041 | |aeng|bfre |
---|
043 | |an-cn--- |
---|
086 | 1 |aNH18-1/380-1995E-PDF |
---|
100 | 1 |aBrown, W. C.|q(William Colin) |
---|
245 | 10|aProgress report #3 |h[electronic resource] : |bmeasured pressure equalized performance of two precast concrete panels : performance of pressure equalized rainscreen walls, a collaborative research and development project / |cauthor, William C. Brown ; author, James M. Ullett ; author, W. Alan Dalgliesh. |
---|
246 | 30|aMeasured pressure equalized performance of two precast concrete panels : |bperformance of pressure equalized rainscreen walls, a collaborative research and development project |
---|
260 | |a[Ottawa] : |bCanada Mortgage and Housing Corporation, |c[1995] |
---|
300 | |aiii, 16, [55] p. : |bill. |
---|
490 | 1 |aResearch report |
---|
500 | |a"Approved: Dr. S.A. Barakat, Head, Building Performance Laboratory." |
---|
500 | |a"Report date: May 31, 1995." |
---|
520 | |a"This report presents data from the experimental evaluation of two precast concrete sandwich panels which were supplied by the Canadian Precast Concrete Institute (CPCI). Each test specimen is 2.40 m high by 1.19 m. wide, and consists of a 100 mm thick precast concrete inner slab which acts as the air barrier, 50 mm of extruded polystyrene insulation, a 13 mm cavity, and a 64 mm precast concrete outer slab which acts as the rainscreen. The inner and outer slabs are connected by two vertical stainless steel trusses located 610 mm apart. The cavity of one specimen (Specimen 3) is a 13 mm air space, while the cavity of the other specimen (Specimen 4) is formed using 13 mm deep Miradrain™. Both cavities extend over the height and the width of the specimen. The experimental evaluation task consisted of pressure equalization, slab deflection, water penetration, and air leakage sub-tasks"--Executive summary, p. 1. |
---|
546 | |aIncludes abstract in French. |
---|
692 | 07|2gccst|aHousing |
---|
692 | 07|2gccst|aConstruction materials |
---|
692 | 07|2gccst|aTesting |
---|
700 | 1 |aUllett, James M. |
---|
700 | 1 |aDalgliesh, W. A.|q(William Alan) |
---|
710 | 2 |aBuilding Performance Laboratory (Canada) |
---|
710 | 2 |aCanada Mortgage and Housing Corporation. |
---|
830 | #0|aResearch report (Canada Mortgage and Housing Corporation : Online)|w(CaOODSP)9.506068 |
---|
856 | 40|qPDF|s3.12 MB|uhttps://publications.gc.ca/collections/collection_2017/schl-cmhc/nh18-1/NH18-1-380-1995-eng.pdf |
---|