000
| 02806nam 2200361za 4500 |
---|
001 | 9.831187 |
---|
003 | CaOODSP |
---|
005 | 20221107145709 |
---|
007 | cr ||||||||||| |
---|
008 | 170124s1987 oncado ob f000 0 eng d |
---|
040 | |aCaOODSP|beng |
---|
043 | |an-cn--- |
---|
086 | 1 |aNH18-1/400-1987E-PDF |
---|
245 | 04|aThe influence of termination configuration on the flow performance of flues |h[electronic resource] / |ca study prepared for Canada Mortgage and Housing Corporation by Scanada Consultants Limited, Scanada Sheltair Consortium Inc. |
---|
246 | 17|aInfluence of flue termination configuration |
---|
260 | |a[Ottawa] : |bCanada Mortgage and Housing Corporation, |c[1987] |
---|
300 | |axi, 67 p. : |bill. |
---|
490 | 1 |aResearch report |
---|
500 | |aCover title. |
---|
500 | |a"Principal Consultants: John C. Haysom, Michael C. Swinton." |
---|
500 | |a"June 11, 1987." |
---|
504 | |aIncludes bibliographical references (p. 31). |
---|
505 | 00|tThe influence of termination configuration on the flow performance of flues /|ra study prepared for Canada Mortgage and Housing Corporation by Scanada Consultants Limited, Scanada Sheltair Consortium Inc. --|gAppendix A.|tExtract from Standard UL 441 "standard for gas vents" --|gAppendix B.|tDetails of termination configurations tested --|gAppendix C.|tPerformance testing of chimney flue caps /|rRowan Williams Davies & Irwin Inc. --|gAppendix D.|tFurther analysis of laboratory test results. |
---|
520 | 3 |a"As part of its ongoing study of combustion venting problems in Canadian houses, Canada Mortgage and Housing Corporation engaged the Scanada Sheltair Consortium to conduct studies of several aspects of chimney flue performance, including: the influence of thermal and flow design parameters on the performance of chimneys, the performance of flues shared by gas furnaces and water heaters, the influence of flue caps and dampers on chimney performance, and the performance of sealed, insulated venting systems for oil furnaces. This report deals with one part of one of the above studies – the influence of flue caps on flue performance. The title has been changed to mention termination configuration rather than caps because performance data on capless flues is also of interest. The other studies are reported on separately"--Intro., p. 1. |
---|
692 | 07|2gccst|aHousing |
---|
692 | 07|2gccst|aHeating |
---|
692 | 07|2gccst|aTesting |
---|
700 | 1 |aHaysom, John C. |
---|
700 | 1 |aSwinton, M. C. |
---|
710 | 1 |aCanada. |bCanada Mortgage and Housing Corporation. |bResearch Division. |
---|
710 | 2 |aScanada Consultants Limited. |
---|
830 | #0|aResearch report (Canada Mortgage and Housing Corporation : Online)|w(CaOODSP)9.506068 |
---|
856 | 40|qPDF|s3.72 MB|uhttps://publications.gc.ca/collections/collection_2017/schl-cmhc/nh18-1/NH18-1-400-1987-eng.pdf |
---|