24500|aPerformance monitoring of a brick veneer/steel stud wall system |h[electronic resource] : |bphase 2 results / |csubmitted by Keller Engineering Associates Inc.
260 |a[Ottawa] : |bCanada Mortgage and Housing Corporation, |c1995.
300 |a1 v. (various pagings) : |bcol. charts, ill.
500 |aIssued also in French under title: Étude de performance d'un système de murs à ossature d'acier recouverte d'un placage de brique : résultats de la phase 2.
500 |a"Report date: 1995 02 17."
500 |aDigitized edition from print [produced by Canada Mortgage and Housing Corporation].
504 |aIncludes bibliographic references.
520 |a"Phase 2 of this study by KEA involved a second year (1992/93) of in-situ performance monitoring of a BV/SS wall system, with respect to air and moisture movements as well as temperature gradients. The performance of a test wall was monitored using various temperature, moisture and air pressure sensors that were connected to an automatic data logging system. In addition, inspection openings were made in the test wall after the 1992/93 monitoring work was completed, in order to verify the results of the data analysis"—Abstract.
69207|2gccst|aConstruction industry
7102 |aKeller Engineering Associates Inc.
7102 |aCanada Mortgage and Housing Corporation.
77508|tÉtude de performance d'un système de murs à ossature d'acier recouverte d'un placage de brique : |w(CaOODSP)9.853565
7760#|tPerformance monitoring of a brick veneer/steel stud wall system : |w(CaOODSP)9.646313
85640|qPDF|s1.66 MB|uhttps://publications.gc.ca/collections/collection_2018/schl-cmhc/nh15/NH15-140-1995-eng.pdf