000 02974cam  2200409za 4500
0019.855837
003CaOODSP
00520221107155409
007cr |||||||||||
008180426s1991    onco   #ob   f000 0 eng d
040 |aCaOODSP|beng
041 |aeng|bfre
043 |an-cn---
0861 |aNH15-802/1991E-PDF
24500|aOPTIMIZE |h[electronic resource] : |ba method for estimating embodied and lifecycle energy and environmental impact of a house (report) / |cprepared by: Sheltair Scientific Ltd. with SAR Engineering Ltd. ... [et al.].
24610|aMethod for estimating embodied and lifecycle energy and environmental impact of a house (report)
260 |aOttawa : |bCanada Mortgage and Housing Corporation, Research Division, |c1991.
300 |ax, 37 p. : |bphotographs + |eAppendices (1 v. (various pagings))
500 |a"October, 1991."
500 |aTitle from cover.
500 |a"CMHC Project Office Peter Russell."
500 |aIssued also in French under title: OPTIMIZE : méthode servant à évaluer l'énergie intrinsèque du cycle de vie d'une habitation et son impact sur l'environnement (rapport).
500 |aDigitized edition from print [produced by Canada Mortgage and Housing Corporation].
504 |aIncludes bibliographical references.
520 |a"This report describes a method for estimating the lifecycle energy requirements of a house and its environmental impact as measured in terms of both outdoor and indoor pollutant generation. It also describes how a lifecycle cost may be determined that includes external or societal costs. A computer programme OPTIMIZE, based on an Excel spreadsheet, permits a user to determine values for the aforementioned factors on a house specific basis. The report and programme focus on the energy required to construct a house, namely the embodied energy. This is derived from the Statistics Canada economic input-output model from which energy usage by all parts of the economy can be computed. Operating energy determination relies on other already established methods. The programme contains a detailed example of a 1991 built 3-bedroom Canadian house of conventional construction together with default values for other numerous input requirements"--Executive summary, p. vi.
546 |aIncludes abstract in French.
69207|2gccst|aHousing
69207|2gccst|aEnergy use
69207|2gccst|aEnvironmental impact
7001 |aRussell, Peter.
7102 |aCanada Mortgage and Housing Corporation. |bResearch Division.
7102 |aSheltair Scientific Ltd.
7102 |aSAR Engineering Ltd.
7102 |aCanada Mortgage and Housing Corporation.
77508|tOPTIMIZE |w(CaOODSP)9.864653
85640|qPDF|s1.52 MB|uhttps://publications.gc.ca/collections/collection_2018/schl-cmhc/nh15/NH15-802-1991-eng.pdf|zReport
85640|qPDF|s4.65 MB|uhttps://publications.gc.ca/collections/collection_2018/schl-cmhc/nh15/NH15-802-1991-1-eng.pdf|zAppendices