000 01939cam  2200349za 4500
0019.861999
003CaOODSP
00520221107160911
007cr |||||||||||
008180914s1971    onc ||||o    f000 0 eng d
040 |aCaOODSP|beng
043 |an-cn---
0861 |aEn36-515/45E-PDF
1001 |aGoulden, P. D.
24514|aThe determination of the phosphorus content of detergents |h[electronic resource] / |cP.D. Goulden, W.J. Traversy and M. Comba.
260 |aOttawa : |bDept. of Energy, Mines and Resources, Inland Waters Branch, |c1971.
300 |av, 9 p.
4901 |aTechnical bulletin ; |vno. 45
500 |aDigitized edition from print [produced by Environment and Climate Change Canada].
504 |aIncludes bibliographical references.
520 |a"This publication describes the procedures used in the Water Quality Division laboratories to determine the phosphorus concentration of detergents. A manual method published by the American Society for Testing and Materials (ASTM), modified to overcome the interference from borates, is used to analyze samples that have a phosphorus concentration close to the 20% P205 maximum specified in the Phosphorus Concentration Control Regulations. An automated method has been developed, using "Technicon AutoAnalyzer" equipment, that enables detergent samples to be screened for phosphorus content at a rate of 20 samples per hour"--Summary.
69207|2gccst|aToxicology
693 4|aDetergents
693 4|aPhosphorus
7001 |aComba, M. E.
7001 |aTraversy, W. J.
7101 |aCanada. |bEnvironment Canada.
7101 |aCanada. |bInland Waters Branch.
7101 |aCanada. |bDepartment of Energy, Mines and Resources.
830#0|aTechnical bulletin (Canada. Inland Waters Branch)|vno. 45|w(CaOODSP)9.861115
85640|qPDF|s409 KB|uhttps://publications.gc.ca/collections/collection_2018/eccc/En36-515-45-eng.pdf