A comparative method apparatus and standards for measurement of thermal conductivity / V.V. Mirkovich, Mineral Processing Division.: M38-1/156-1965E-PDF
"A comparative method thermal conductivity apparatus was designed. The precision of measurements was determined by measuring the conductivity of alumina with standards made of the same alumina. The accuracy of measurements was determined by cross-checking the conductivities of alumina, forsterite, Pyroceram Code 9606 and titanium carbide. The thermal stabilities of Pyroceram Code 9606 and zirconia were examined in order to establish their values as thermal conductivity reference materials. It was concluded that: 1) with this apparatus, accurate thermal conductivity data can be obtained; and 2) Pyroceram Code 9606 can be recommended for use as a primary standard for the low thermal conductivity range"--Synopsis, page i.
Permanent link to this Catalogue record:
publications.gc.ca/pub?id=9.869732&sl=0
| Department/Agency |
|
|---|---|
| Title | A comparative method apparatus and standards for measurement of thermal conductivity / V.V. Mirkovich, Mineral Processing Division. |
| Series title |
|
| Publication type | Monograph - View Master Record |
| Language | [English] |
| Format | Digital text |
| Electronic document | |
| Note(s) |
|
| Publishing information |
|
| Author / Contributor |
|
| Description | 1 online resource (v, 19 pages) : charts, figure. |
| Catalogue number |
|
| Subject terms |
Request alternate formats
To request an alternate format of a publication, complete the Government of Canada Publications email form. Use the form’s “question or comment” field to specify the requested publication.Page details
- Date modified: