000
| 02761nam 2200421zi 4500 |
---|
001 | 9.895703 |
---|
003 | CaOODSP |
---|
005 | 20221107174113 |
---|
006 | m o d f |
---|
007 | cr cn||||||||| |
---|
008 | 210126e202009 onc ob f000 0 eng d |
---|
020 | |z9780660086347|q(incorrect) |
---|
040 | |aCaOODSP|beng|erda|cCaOODSP |
---|
043 | |an-cn--- |
---|
086 | 1 |aCC172-80/2020E-PDF|zCC172-80/2017E-PDF |
---|
245 | 00|aDesign, testing and performance of exposure devices. |
---|
250 | |aVersion 1.1. |
---|
264 | 1|aOttawa, ON : |bCanadian Nuclear Safety Commission = Commission canadienne de sûreté nucléaire, |cSeptember 2020. |
---|
264 | 4|c©2020 |
---|
300 | |a1 online resource (i page, 1 unnumbered page, 10 pages). |
---|
336 | |atext|btxt|2rdacontent |
---|
337 | |acomputer|bc|2rdamedia |
---|
338 | |aonline resource|bcr|2rdacarrier |
---|
490 | 1 |aRegulatory document ; |vREGDOC-2.5.7 |
---|
500 | |aIssued also in French under title: Conception, essais et rendement des appareils d'exposition. |
---|
500 | |aAt head of title: Physical design. |
---|
500 | |aIssued also in HTML format. |
---|
504 | |aIncludes bibliographical references. |
---|
520 | |a"Industrial radiography is regulated by the Canadian Nuclear Safety Commission (CNSC). It is a non-destructive testing method that uses high-activity sealed radioactive sources to examine the structure of welds, castings and building components, in order to identify flaws and errors or to ensure that work in an area will not affect hidden existing systems, such as pipes and electrical wires. The advantages of using exposure devices for non-destructive testing are that they are highly portable, require no external power sources, and can be used in various field settings. Regulatory document REGDOC -2.5.7, Design, Testing and Performance of Exposure Devices, Version 1.1 provides guidance in the design, testing and performance of exposure devices, in order to apply for the certification of the radiation device under section 12 of the NSRD Regulations"--Preface, page i. |
---|
650 | 0|aRadioactive substances|xSafety regulations|zCanada. |
---|
650 | 0|aRadiography, Industrial|zCanada|xEquipment and supplies. |
---|
710 | 2 |aCanadian Nuclear Safety Commission, |eissuing body. |
---|
775 | 08|tConception, essais et rendement des appareils d'exposition.|w(CaOODSP)9.895704 |
---|
795 | |tPhysical design |w9.837260 |
---|
830 | #0|aRegulatory document (Canadian Nuclear Safety Commission)|vREGDOC-2.5.7.|w(CaOODSP)9.505296 |
---|
856 | 40|qPDF|s683 KB|uhttps://publications.gc.ca/collections/collection_2021/ccsn-cnsc/CC172-80-2020-eng.pdf |
---|
856 | 4 |qHTML|sN/A|uhttps://nuclearsafety.gc.ca/eng/acts-and-regulations/regulatory-documents/published/html/regdoc2-5-7-v1-1/index.cfm |
---|