Formulae for mass median and mass mean drop diameters (U) / by J. Monaghan, G.A. Hill and W.G. Soucey.: DR52-6/3-1981E-PDF

"Formulae are derived to calculate the mass median (DO) and mass mean (DM) diameters of droplets in sprays. These formulae are based on an inverse exponential relationship which is empirically observed to occur in liquid sprays. The median diameter divides the total mass of liquid in half while the mean diameter represents a more commonly used statistical average for identifying random samples. The formulae are used to describe the characteristics of a typical set of experimental drop data and are compared to conventional formulae for calculating these parameters"--abstract.

Permanent link to this Catalogue record:
publications.gc.ca/pub?id=9.927448&sl=0

Publication information
Department/Agency Defence Research Establishment Suffield, issuing body.
Title Formulae for mass median and mass mean drop diameters (U) / by J. Monaghan, G.A. Hill and W.G. Soucey.
Series title Suffield memorandum ; no. 1014
Publication type Series - View Master Record
Language [English]
Format Electronic
Electronic document
Note(s) "PCN No. 13E10"--cover.
Digitized edition from print [produced by Defence Research and Development Canada].
Includes bibliographical references (page 8).
Publishing information Ralston, Alberta : Defence Research Establishment Suffield, September 1981.
Author / Contributor Monaghan, J., author.
Description 1 online resource (13, [7] pages) : charts
Catalogue number
  • DR52-6/3-1981E-PDF
Departmental catalogue number M-1014
Subject terms Drops -- Measurement.
Gouttes -- Mesure.
Request alternate formats
To request an alternate format of a publication, complete the Government of Canada Publications email form. Use the form’s “question or comment” field to specify the requested publication.
Date modified: