The effect of vertical alignment on the performance of the price 622AA current meter / by P. Engel and C. DeZeeuw.En36-539/95-1979E-PDF

"The results of this study, which shows the Price current meter is very sensitive to its azimuth angle, were quite unexpected. Bearing in mind the widespread use of this meter for recording the water resources of Canada, it is evidently important that operators and surveyors should be made aware of this characteristic of the meter. The results should be incorporated in operational manuals"--Management perspective, page i.

Permanent link to this Catalogue record:
publications.gc.ca/pub?id=9.931626&sl=0

Publication information
Department/Agency
  • National Water Research Institute (Canada). Hydraulics Division, issuing body.
  • Canada Centre for Inland Waters, issuing body.
TitleThe effect of vertical alignment on the performance of the price 622AA current meter / by P. Engel and C. DeZeeuw.
Series title
  • [Unpublished manuscript]
Publication typeMonograph - View Master Record
Language[English]
FormatDigital text
Electronic document
Note(s)
  • "July 1979."
  • Digitized edition from print [produced by Environment and Climate Change Canada].
  • Includes bibliographical references (page 10).
  • Includes management perspective and summary in English and French.
Publishing information
  • Burlington, Ontario : Canada Centre for Inland Waters, National Water Research Institute, Hydraulics Division, 1979.
  • ©1979
Author / Contributor
  • Engel, P., author.
Description1 online resource (vi, 10 pages, 16 unnumbered pages) : illustrations, graphs.