<?xml version="1.0" encoding="UTF-8"?><marc:collection xmlns:marc="http://www.loc.gov/MARC21/slim">
  <marc:record>
    <marc:leader>00000nam  2200000za 4500</marc:leader>
    <marc:controlfield tag="001">9.807442</marc:controlfield>
    <marc:controlfield tag="003">CaOODSP</marc:controlfield>
    <marc:controlfield tag="005">20240219183357</marc:controlfield>
    <marc:controlfield tag="007">cr |||||||||||</marc:controlfield>
    <marc:controlfield tag="008">150723s2015    oncdo   ob   f000 0 eng d</marc:controlfield>
    <marc:datafield tag="040" ind1=" " ind2=" ">
      <marc:subfield code="a">CaOODSP</marc:subfield>
      <marc:subfield code="b">eng</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="041" ind1=" " ind2=" ">
      <marc:subfield code="a">eng</marc:subfield>
      <marc:subfield code="b">fre</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="043" ind1=" " ind2=" ">
      <marc:subfield code="a">n-cn---</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="086" ind1="1" ind2=" ">
      <marc:subfield code="a">D68-2/12-2015E-PDF</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="100" ind1="1" ind2=" ">
      <marc:subfield code="a">Abel, Sharon M.</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="245" ind1="1" ind2="4">
      <marc:subfield code="a">The effect of integrated hearing protection surround levels on sound localization </marc:subfield>
      <marc:subfield code="h">[electronic resource] / </marc:subfield>
      <marc:subfield code="c">Sharon M. Abel, Craig Burrell, Douglas Saunders.</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="260" ind1=" " ind2=" ">
      <marc:subfield code="a">[Ottawa] : </marc:subfield>
      <marc:subfield code="b">Defence Research and Development Canada, </marc:subfield>
      <marc:subfield code="c">2015. </marc:subfield>
    </marc:datafield>
    <marc:datafield tag="300" ind1=" " ind2=" ">
      <marc:subfield code="a">vi, 20, [2] p. : </marc:subfield>
      <marc:subfield code="b">fig., graphs, tables.</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="490" ind1="1" ind2=" ">
      <marc:subfield code="a">Scientific report ; </marc:subfield>
      <marc:subfield code="v">2015-R012</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="500" ind1=" " ind2=" ">
      <marc:subfield code="a">February 2015.</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="504" ind1=" " ind2=" ">
      <marc:subfield code="a">Includes bibliographical references (p. 17-18).</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="520" ind1=" " ind2=" ">
      <marc:subfield code="a">Advanced hearing protection technologies enhance speech understanding while protecting against injurious noise. This experiment assessed horizontal plane sound localization with three communication devices with integrated hearing protection that could amplify environmental sounds. Normal-hearing adults localized a brief noise burst with ears unoccluded and fitted with the Nacre QUIETPRO earplug, Peltor PowerCom Plus earmuff, and Sensear SDP earmuff-earplug combination. These were tested in the passive OFF mode and in the active ON mode at three volume settings. The stimulus was presented by an array of eight loudspeakers surrounding the listener. One block of 80 randomized loudspeaker identification trials was presented under each listening condition. Participants responded using a response box with eight buttons in the same configuration as the array. With ears unoccluded, mean scores were above 90% correct. With the devices in the OFF mode, mean scores were less than 50%, mainly due to confusion of front and back. With the devices ON, an improvement of 21% to 33% was realized. Azimuthal percent correct was highest for sound sources located on either side of the midline axis in front, decreasing front to back, reflecting the placement of the external microphones on the devices. Increasing the volume had no effect.</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="692" ind1="0" ind2="7">
      <marc:subfield code="2">gccst</marc:subfield>
      <marc:subfield code="a">Military technology</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="700" ind1="1" ind2=" ">
      <marc:subfield code="a">Burrell, Craig,</marc:subfield>
      <marc:subfield code="d">1975-</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="710" ind1="2" ind2=" ">
      <marc:subfield code="a">Defence R&amp;D Canada.</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="830" ind1="#" ind2="0">
      <marc:subfield code="a">Scientific report (Defence R&amp;D Canada)</marc:subfield>
      <marc:subfield code="v">2015-R012</marc:subfield>
      <marc:subfield code="w">(CaOODSP)9.802305</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="856" ind1="4" ind2="0">
      <marc:subfield code="q">PDF</marc:subfield>
      <marc:subfield code="s">864 KB</marc:subfield>
      <marc:subfield code="u">https://publications.gc.ca/collections/collection_2015/rddc-drdc/D68-2-12-2015-eng.pdf</marc:subfield>
    </marc:datafield>
    <marc:datafield tag="986" ind1=" " ind2=" ">
      <marc:subfield code="a">DRDC-RDDC-2015-R012</marc:subfield>
    </marc:datafield>
  </marc:record>
</marc:collection>