000 02850cam  2200337za 4500
0019.831039
003CaOODSP
00520221107145649
007cr |||||||||||
008170123s1990    oncado  ob   f000 0 eng d
040 |aCaOODSP|beng
043 |an-cn---
0861 |aNH18-1/394-1990E-PDF
1001 |aDrysdale, Robert G.
24513|a[A report on tests of full scale brick veneer/steel stud walls to determine strength and rain penetration characteristics] |h[electronic resource] / |c[prepared for Project Implementation Division, Canada Mortgage and Housing Corporation by Robert G. Drysdale and Michael J. Wilson].
2461 |iAdded cover title: |aTests of full scale brick veneer/steel stud walls to determine strength and rain penetration characteristics
260 |a[Ottawa] : |bCanada Mortgage and Housing Corporation, |c[1990]
300 |ax, 280 p. : |bill.
4901 |aResearch report
500 |aImperfect: cov. and/or t.p. are missing from this digitized edition.
500 |a"Part 5 of the McMaster University laboratory test program on brick veneer/steel stud wall systems"--Cf. cov. of print ed.
504 |aIncludes bibliographical references (p. 222-238).
5050 |ac. 1. Introduction -- c. 2. Description of the test apparatus and test procedures -- c. 3. Material properties and fabrication of test specimens -- c. 4. Rain penetration program -- c. 5. Structural test results -- c. 6. Summary, conclusions and recommendations -- app. 1. Masonry material test results -- app. 2. Specimen test sequences -- app. 3. Rain penetration test results -- app. 4. Summary of structural response at a pressure of 500 Pa.
5203 |a“The design, construction and physical testing of five full scale (2.75 m x 5.2 m) brick veneer rain screen wall specimens are reported. Also, the documentation of the design and fabrication of a new test apparatus and of the development of test procedures are major components of the report. The test program included sequences of air pressure loading stages both with and without simulated rain to establish both the structural and rain penetration performance of the test walls. The test walls included four brick veneer/steel stud specimens and one brick veneer/concrete block specimen. Additional tests were performed on bricks, mortar and masonry assemblages to define relevant characteristics"--Abstract, p. v.
69207|2gccst|aConstruction materials
69207|2gccst|aDesign
69207|2gccst|aTesting
7001 |aWilson, Michael J.
7101 |aCanada.|bCanada Mortgage and Housing Corporation.|bProject Implementation Division.
830#0|aResearch report (Canada Mortgage and Housing Corporation : Online)|w(CaOODSP)9.506068
85640|qPDF|s5.50 MB|uhttps://publications.gc.ca/collections/collection_2017/schl-cmhc/nh18-1/NH18-1-394-1990-eng.pdf