Analysis of oxygenated solvents in groundwater by dynamic thermal stripping-GC-MSD / by M.W. Priddle, S. Lesage and R.E. Jackson. : En13-5/90-54E-PDF
"A plume of groundwater contaminated with 1,4-dioxane tetrahydrofuran and acetone emanating from a solvent disposal site was mapped. Analysis was conducted with dynamic thermal stripping followed by thermal desorption into a GC-MSD with monitoring of selected ions. This method has a significantly better practical quantitation limit than the current EPA method (10 vs. 150 µg/L for 1,4-dioxane). Ten years after disposal, concentrations of 1,4-dioxane greater than 3 mg/L were measured at points more than 300 m from the site"--Abstract.
Lien permanent pour cette publication :
publications.gc.ca/pub?id=9.870522&sl=1
| Ministère/Organisme |
|
|---|---|
| Titre | Analysis of oxygenated solvents in groundwater by dynamic thermal stripping-GC-MSD / by M.W. Priddle, S. Lesage and R.E. Jackson. |
| Titre de la série |
|
| Type de publication | Monographie - Voir l'enregistrement principal |
| Langue | [Anglais] |
| Format | Texte numérique |
| Document électronique | |
| Note(s) |
|
| Information sur la publication |
|
| Auteur / Contributeur |
|
| Description | 1 online resource (4 unnumbered pages, 7 pages, 2 unnumbered pages) : illustrations. |
| Numéro de catalogue |
|
| Descripteurs |
Demander des formats alternatifs
Pour demander une publication dans un format alternatif, remplissez le formulaire électronique des publications du gouvernement du Canada. Utilisez le champ du formulaire «question ou commentaire» pour spécifier la publication demandée.Détails de la page
- Date de modification :