000
| 03093nam 2200409zi 4500 |
---|
001 | 9.870555 |
---|
003 | CaOODSP |
---|
005 | 20221107163139 |
---|
006 | m o d f |
---|
007 | cr mn||||||||| |
---|
008 | 190325t20192019onca ob f000 0 eng d |
---|
020 | |a9780660302584 |
---|
040 | |aCaOODSP|beng|erda|cCaOODSP |
---|
086 | 1 |aNR24-36/2019E-PDF |
---|
100 | 1 |aKo, Yoon J., |eauthor. |
---|
245 | 10|aLiterature review on the use of water mist system for the protection of wood frame buildings / |cauthor(s), Yoon Ko, Max Kinateder, Nour Elsagan, Alex Bwalya. |
---|
264 | 1|a[Ottawa] : |bNational Research Council Canada = Conseil national de recherches Canada, |c2019. |
---|
264 | 4|c©2019 |
---|
300 | |a1 online resource (35 pages) : |billustrations (some colour) |
---|
336 | |atext|btxt|2rdacontent |
---|
337 | |acomputer|bc|2rdamedia |
---|
338 | |aonline resource|bcr|2rdacarrier |
---|
500 | |aAt head of title: Construction. |
---|
500 | |a"Report no.: A1-014711.1." |
---|
500 | |a"Report date: Mar. 31st, 2019." |
---|
504 | |aIncludes bibliographical references (pages 34-35). |
---|
520 | |a"This report reviews current building regulations and standard requirements for the use of water mist systems for the protection of wood frame buildings. To identify research gaps, previous experimental studies were also reviewed. It is found that there are very limited studies conducted to develop guidelines or design methods for water mist systems in protection of buildings. Although several water mist standards provide test protocols for using water mist systems in residential and light hazards scenarios, none of these standards considered the use of water mist systems in wood frame buildings. Therefore, without verifications, these existing standards and test protocols should not be incorporated in the use of water mist systems in protection of timber buildings. In addition, development of new test protocols is in need since building codes are evolving to allow various occupancies for timber buildings. Test protocols need to be developed to address important design parameters, such as compartment conditions, fire scenarios and water delivery systems including nozzles. It should be noted that the occupancy, volumes of compartments, ventilation conditions need to be considered in selection of the nozzles and designing layouts of water delivery systems"--Executive summary, page v. |
---|
530 | |aIssued also in print format. |
---|
650 | 0|aFire sprinklers. |
---|
650 | 0|aFire extinction|xEquipment and supplies. |
---|
650 | 0|aWooden-frame buildings|xFires and fire prevention. |
---|
650 | 6|aExtincteurs automatiques. |
---|
650 | 6|aIncendies Extinction|xAppareils et matériel. |
---|
650 | 6|aConstructions à ossature de bois|xIncendies et prévention des incendies. |
---|
710 | 2 |aNational Research Council Canada, |eissuing body. |
---|
776 | 0#|tLiterature review on the use of water mist system for the protection of wood frame buildings.|w(CaOODSP)9.870556 |
---|
856 | 40|qPDF|s1.39 MB|uhttps://publications.gc.ca/collections/collection_2020/cnrc-nrc/NR24-36-2019-eng.pdf |
---|