000 02907nam  2200457zi 4500
0019.895023
003CaOODSP
00520221107173917
006m     o  d f      
007cr bn|||||||||
008210105e198303  oncab   obt  f000 0 eng d
040 |aCaOODSP|beng|erda|cCaOODSP
043 |an-cn-mb
045 |ax7x7
0861 |aCo24-3/7-1362-1983E-PDF
1001 |aLauber, W. R., |eauthor.
24510|aMeasurements and modelling of the HF radio noise environment near an HVDC converter station / |cby W.R. Lauber and J.M. Bertrand.
264 1|aOttawa : |bCommunications Research Centre, |cMarch 1983.
300 |a1 online resource (iii, 57 pages) : |billustrations, map.
336 |atext|btxt|2rdacontent
337 |acomputer|bc|2rdamedia
338 |aonline resource|bcr|2rdacarrier
4901 |aCRC report ; |vno. 1362
500 |a"Radar and Communications Technology Branch."
500 |aDigitized edition from print [produced by Innovation, Science and Economic Development Canada].
500 |aSome pages rotated in this copy.
504 |aIncludes bibliographical references (pages 44-46).
5203 |a"Measurements of the HF radio noise environment near an HVDC transmission line and converter station were made outside Winnipeg in July 1977. Typical levels and characteristics are presented for various combinations of mercury arc valve noise, AC hum and DC corona from a number of sites within eight kilometres of the converter station. In addition, two sets of measurements were taken 80 km from the converter station. Values of the root-mean-square, average and quasipeak voltages were calculated from the Amplitude Probability Distributions (APDs) of the noise and were found to compare favourably with the directly measured values. Four mathematical models, the Rayleigh and three others which were developed for atmospheric noise were fitted to the measured APD data. Using inputs of Vrms and Vd the Log-Normal model produced the most accurate predictions of the measured APDs. The Log-Normal and the Hall models both fitted the measured Average Crossing Rate data equally well"--Abstract, page 1.
530 |aIssued also in print format.
650 0|aRadio noise|zManitoba|xMeasurement.
650 0|aRadio noise|zManitoba|xMathematical models.
650 0|aElectric lines|zManitoba.
650 0|aElectric substations|zManitoba.
650 6|aBruit radioélectrique|zManitoba|xMesure.
650 6|aBruit radioélectrique|zManitoba|xModèles mathématiques.
650 6|aLignes électriques|zManitoba.
650 6|aPostes de réseau électrique|zManitoba.
7102 |aCommunications Research Centre (Canada), |eissuing body.
830#0|aCRC report ;|vno. 1362.|w(CaOODSP)9.882492
85640|qPDF|s1.43 MB|uhttps://publications.gc.ca/collections/collection_2021/isde-ised/co24/Co24-3-7-1362-1983-eng.pdf