Source level calibration of the DREA moving coil projector / John C. Osler - David M.F. Chapman ; approved by C.W. Bright. : D68-21/44-1995E-PDF
"The Defence Research Establishment Atlantic moving coil projector (MCP) generates acoustic power at low frequencies (below 250 Hz) by displacing water with two pistons which oscillate in phase. The source level of the MCP must be continually monitored because it varies in accordance with the operating state of the projector. Source level as a function of time may be determined by combining measurements of the acceleration of the forward and aft pistons in an appropriate manner. This document establishes the methodology to use in this process by comparing at-sea measured transmission loss of CW signals to theoretical calculations. This comparison reveals that corrections are required to the source level derived from the MCP accelerometers at the higher end of its frequency range"--Abstract, page ii.
Lien permanent pour cette publication :
publications.gc.ca/pub?id=9.951551&sl=1
| Ministère/Organisme |
|
|---|---|
| Titre | Source level calibration of the DREA moving coil projector / John C. Osler - David M.F. Chapman ; approved by C.W. Bright. |
| Titre de la série |
|
| Type de publication | Monographie - Voir l'enregistrement principal |
| Langue | [Anglais] |
| Format | Texte numérique |
| Document électronique | |
| Note(s) |
|
| Information sur la publication |
|
| Auteur / Contributeur |
|
| Description | 1 online resource (v, 30 pages) : graphs, photographs. |
| Numéro de catalogue |
|
| Descripteurs |
Demander des formats alternatifs
Pour demander une publication dans un format alternatif, remplissez le formulaire électronique des publications du gouvernement du Canada. Utilisez le champ du formulaire «question ou commentaire» pour spécifier la publication demandée.Détails de la page
- Date de modification :