1001 |aPoirier, Jean-Philippe B., |eauthor.
24510|aEvaluating the reproducibility of CSA SPE-07:23 using two centrally ducted air-source cold-climate heat pumps / |cprepared by: Jean-Philippe B. Poirier, Jeremy Sager, Bruce Harley.
264 1|a[Ottawa] : |bNatural Resources Canada = Ressources naturelles Canada, |c30 April 2025.
264 4|c©2025
300 |a1 online resource (ix, 83 pages) : |bcharts, illustrations
336 |atext|btxt|2rdacontent
337 |acomputer|bc|2rdamedia
338 |aonline resource|bcr|2rdacarrier
500 |aCover title.
500 |aIssued also in French under title: Évaluation de la reproductibilité de la norme CSA SPE-07:23 à l'aide de deux thermopompes pour climat froid à conduit central.
500 |a"Prepared for: Natural Resources Canada - Office of Energy Efficiency – Equipment Division, Northwest Energy Efficiency Alliance."
504 |aIncludes bibliographical references (pages 77-78).
520 |a"In this report, CanmetENERGY-Ottawa evaluated the reproducibility of the CSA SPE-07:23 (SPE07) test procedure using two centrally ducted cold-climate air-source heat pumps (CC-ASHP). Both CC-ASHPs were 2-ton variable speed systems with communicating thermostats that had previously been field and lab tested for evaluations of representativeness and repeatability. The objective was to produce heating and cooling seasonal COPs (SCOPC and SCOPH) from a complete series of SPE-07 rating tests using the same building load line and equipment installation as that used during previous testing conducted in another laboratory"--Executive Summary, page ii.
650 0|aHeat pumps|zCanada.
7101 |aCanada. |bNatural Resources Canada, |eissuing body.
7102 |aCANMET Energy Technology Centre (Canada), |eissuing body.
77508|tÉvaluation de la reproductibilité de la norme CSA SPE-07:23 à l'aide de deux thermopompes pour climat froid à conduit central / |w(CaOODSP)9.957521
85640|qPDF|s3.53 MB|uhttps://publications.gc.ca/collections/collection_2026/rncan-nrcan/M154-199-2025-eng.pdf