Performance of float actuated water level recorder systems / by Peter Engel.: En13-5/87-67E-PDF
"A theoretical analysis complemented by experimental measurements was used to examine the behaviour of float activited water level recorder systems when used with the Stevens A-71 recorder. The equations developed can be used to predict measurement errors for any type of float type recording installation. The results show that for typical Water Survey of Canada installations, errors in measuring water levels can be kept to less than 3mm (0.01 ft.)"--Summary, page iii.
Permanent link to this Catalogue record:
publications.gc.ca/pub?id=9.867950&sl=0
| Department/Agency |
|
|---|---|
| Title | Performance of float actuated water level recorder systems / by Peter Engel. |
| Series title |
|
| Publication type | Monograph - View Master Record |
| Language | [English] |
| Format | Digital text |
| Electronic document | |
| Note(s) |
|
| Publishing information |
|
| Author / Contributor |
|
| Description | 1 online resource (vi, 21 pages) : illustrations. |
| Catalogue number |
|
| Subject terms |
Request alternate formats
To request an alternate format of a publication, complete the Government of Canada Publications email form. Use the form’s “question or comment” field to specify the requested publication.Page details