The effect of replacing the multiband transmittance sensor glass window with a plastic lucite SAR window / author: R. Desrosiers.: En13-6/1-83-02E-PDF
"It was found that after many hundred profiles cracks began to appear and spalling occurred near the edges of the glass windows used inthe NWRI multiband transmittance sensor. The glass (Schott BK 7 UVB NVS) window was replaced with a Dupont Lucite SAR (trademark) acrylic window. The structural calculations were discussed in detail in Reference 1. Reference 2 found that temperature cycling was not the likely cause of the problem"--Introduction, page 1.
Permanent link to this Catalogue record:
publications.gc.ca/pub?id=9.874867&sl=0
Department/Agency | Canada. Environment Canada. National Water Research Institute (Canada). Hydraulics Division. |
---|---|
Title | The effect of replacing the multiband transmittance sensor glass window with a plastic lucite SAR window / author: R. Desrosiers. |
Series title | Technical note ; no. ES83-02 |
Publication type | Series - View Master Record |
Language | [English] |
Format | Electronic |
Electronic document | |
Note(s) | Digitized edition from print [produced by Environment and Climate Change Canada]. Title from cover. Includes bibliographical references. |
Publishing information | [Burlington, Ont.] : Hydraulics Division, [National Water Research Institute], April 1983. |
Author / Contributor | Desrosiers, R. J., author. |
Description | 1 online resource (7 pages). |
Catalogue number |
|
Departmental catalogue number | CORRESPONDENCE FILE NO: Study 372 |
Subject terms | Glass |